Det är inte alltför sällan som lokalen eller tomten inte har perfekta mått, utan att det måste trixas och mätas, vändas och vridas och i vissa fall krävs även måttbeställda/skräddarsydda banor. Här finner du fakta, hjälp och råd om hur du bäst kan göra för att få plats med det antal banor som du önskar.
Banana inner dimensions:
Outer dimensions of the track (including construction):
The fire authority's normal requirements for escape route/passage:
Minimum distance between wall and construction:
10x20m
10,6x20,6m
900mm (se skiss nedan)
200mm (se skiss nedan)
Banana inner dimensions:
Outer dimensions of the track (including construction):
The fire authority's normal requirements for escape route/passage:
Minimum distance between wall and construction:
6x20m
6,6x20,6m
900mm
200mm
The inner dimension of a double track is thus 10x20m. Around the track there is a construction that builds 0.3m around, and creates the outer dimension 10.6x20.6m.
Every two meters around the entire course there are anchor plates on which the posts stand. The lighting poles (if you choose lighting on the pole) are marked Z below and have a reinforced pole (see picture below). The red lines below are the glass that is 10mm (Vision / Single) or 12mm (Panoramic / Single Panoramic) thick.
If we immerse ourselves in the construction, then there are anchor plates (which are 10mm thick) on which the post stands (the post is 80mm deep).
The anchor plate protrudes 260-300mm (0.3m) from the inner dimension and is thus the part of the construction that contributes to the width 10.6x20.6.
The posts protrude 80mm except at the lighting posts (see picture to the right) where there is a reinforcement post of an additional 80mm.
Each anchor plate is anchored with 6 anchor bolts.
Note that the anchor plate is thus the one that protrudes the most, while the posts only protrude 90-92mm (the post 80mm plus glass 10 / 12mm) from the inner dimension. The exception is the lighting pole which has an extra reinforcement pole about 600mm high.
Below are the recommended dimensions that we have between the tracks (in cases where the hallway is to be used for fire evacuation) and between the track and the wall (in order to be able to maintain the tracks / polish glass etc)
On the lighting poles there is a connection hatch that looks like the picture to the right.
The measuring tape shows the height from the floor.
The size of the door is:
The door is used to connect the lighting, in cases where you have incoming electricity from below, and cable from the luminaire from above.